Verifying the configuration – H3C Technologies H3C S12500 Series Switches User Manual
Page 426

410
[SwitchD] pim ipv6
[SwitchD-pim6] c-bsr 4002::1 128 10
[SwitchD-pim6] c-rp 4002::1 group-policy 2005
[SwitchD-pim6] quit
# On Switch E, configure the service scope of RP advertisements, specify a C-BSR and a C-RP, and
set the hash mask length to 128 and the priority of the C-BSR to 20.
[SwitchE] acl ipv6 number 2005
[SwitchE-acl6-basic-2005] rule permit source ff0e::101 64
[SwitchE-acl6-basic-2005] quit
[SwitchE] pim ipv6
[SwitchE-pim6] c-bsr 1003::2 128 20
[SwitchE-pim6] c-rp 1003::2 group-policy 2005
[SwitchE-pim6] quit
Verifying the configuration
Use the display pim ipv6 interface command to view the IPv6 PIM configuration and running status
on each interface. For example:
# Display the IPv6 PIM information on all interfaces of Switch A.
[SwitchA] display pim ipv6 interface
Interface NbrCnt HelloInt DR-Pri DR-Address
Vlan100 0 30 1 1001::1
(local)
Vlan101 1 30 1 1002::2
Vlan102 1 30 1 1003::2
To view the BSR election information and the locally configured C-RP information in effect on a
switch, use the display pim ipv6 bsr-info command. For example:
# Display the BSR information and the locally configured C-RP information in effect on Switch A.
[SwitchA] display pim ipv6 bsr-info
Elected BSR Address: 1003::2
Priority: 20
Hash mask length: 128
State: Accept Preferred
Uptime: 00:04:22
Expires: 00:01:46
# Display the BSR information and the locally configured C-RP information in effect on Switch D.
[SwitchD] display pim ipv6 bsr-info
Elected BSR Address: 1003::2
Priority: 20
Hash mask length: 128
State: Elected
Uptime: 00:05:26
Expires: 00:01:45
Candidate BSR Address: 4002::1
Priority: 10
Hash mask length: 128
State: Candidate