Wavetronix Click 500 (programmable controller) (CLK-500) - User Guide User Manual
Page 97
96
CHAPTER 9 • CLICK 512
When you open the 512 tab, you will see ten tabs. The first is labeled Overall. This tab al-
lows you to configure values for the speed and length thresholds (see Figure 9.122 and Table
9.5).
Note
Values in Click Supervisor will be displayed according to the units (English or metric)
selected in SSMHD.
Figure 9.12 – Expert Driver Overall Tab
Setting
Description
Trigger Sync
Sets the method of trigger synchronization. The options are: Auto-
matic (English), Automatic (Metric) or None.
Setback distance
Distance between the sensor and a downstream location on the
roadway. Depending upon the trigger method, the downstream loca-
tion may be the actual location of the roadway sign, or somewhere in
between. If units are English, this distance is in feet; if Metric, then
the distance is in decimeters.
ETA (ms)
If you are not using the ETA trigger method, leave this value at 0.
Otherwise, this is the ETA to the downstream location.
Enable Speed Fail-
safe
In a small percentage of cases, the SmartSensor HD may not report
a valid speed. Check this box if you want vehicles that have an invalid
speed (but that exceed the length threshold) to trigger an output.
Logic AND Outputs
with Input 1
Allows you to gate the activation of outputs based upon an external
signal wired to digital input 1.
Logic AND Outputs
with Input 2
Allows you to gate the activation of outputs based upon an external
signal wired to digital input 2.