CHAPTER 9 CLICK 512

When you open the 512 tab, you will see ten tabs. The first is labeled Overall. This tab al-

lows you to configure values for the speed and length thresholds (see Figure 9.122 and Table

9.5).

Note

Values in Click Supervisor will be displayed according to the units (English or metric)
selected in SSMHD.

Figure 9.12 – Expert Driver Overall Tab

Setting

Description

Trigger Sync

Sets the method of trigger synchronization. The options are: Auto-
matic (English), Automatic (Metric) or None.

Setback distance

Distance between the sensor and a downstream location on the
roadway. Depending upon the trigger method, the downstream loca-
tion may be the actual location of the roadway sign, or somewhere in
between. If units are English, this distance is in feet; if Metric, then
the distance is in decimeters.

ETA (ms)

If you are not using the ETA trigger method, leave this value at 0.
Otherwise, this is the ETA to the downstream location.

Enable Speed Fail-

safe

In a small percentage of cases, the SmartSensor HD may not report
a valid speed. Check this box if you want vehicles that have an invalid
speed (but that exceed the length threshold) to trigger an output.

Logic AND Outputs

with Input 1

Allows you to gate the activation of outputs based upon an external
signal wired to digital input 1.

Logic AND Outputs

with Input 2

Allows you to gate the activation of outputs based upon an external
signal wired to digital input 2.