Wavetronix Click 500 (programmable controller) (CLK-500) - User Guide User Manual
Page 130
CHAPTER 11 • CLICK 514 129
Figure 11.10 – Expert Driver Comm Tab
Setting
Description
Baud Rate
Allows you to change the baud rate at which the device connects to
the sensor.
Flow Control
Is used for configuring hardware handshaking. This option is currently
not available.
Parity
Allows you to set parity error checking. This option is currently not
available.
Stop Bits
Allows you to set the number of stop bits. This option is currently not
available.
Data Bits
Shows you the number of data bits being sent. This option cannot be
changed.
Active Port
Indicates on which port you are communicating with the sensor. This
option cannot be changed.
Latency
Indicates the latency between the sensor and the Click device. This
option cannot be changed.
Table 11.3 – Expert Driver Comm Tab
The Autobaud subtab allows you to configure how the device autobauds (see Figure 11.11
and Table 11.4). As none of these options can currently be changed, you would only use this
tab if you needed to look at how the device’s autobaud function is currently set up.