beautypg.com

Test pattern – Wavetronix Click 500 (programmable controller) (CLK-500) - User Guide User Manual

Page 62

background image

CHAPTER 7 • CLICK 510

61

Note

Only event data packets can be sent, so you cannot emulate the Actuation data
mode used with a contact closure module and the SS105.

Figure 7.4 – Viewing 17’/60’ 30–60 mph Event Trafic Data in HyperTerminal

Test Pattern

Test Pattern mode is the second mode presented in the menu selection process (blue solid).

Test Pattern mode is used for testing communication channels; it does this by sending data

packets over the channel to the other Click 510 or computer. It is especially helpful for de-

bugging because it locates the break in your channel of communication. Use it when you are

connecting two Click 510 devices together or connecting a Click 510 to a computer.

This mode has two submenus on which you can specify the data packet and how it will be

sent.

1st LED

2nd LED

3rd LED

4th LED

Submenu 1

(Yellow LEDs)

1 second

0.25 – 1 second

Switch

-

Submenu 2

(Red LEDs)

LED flash

LED sequence

ASCII sequence

ASCII text

Table 7.3 – Test Pattern Submenus (Yellow and Red LEDs)

Test Pattern submenu 1 allows you to select when the Click 510 sends out data packets.

Submenu 1 selections are displayed on the device as the row of yellow LEDs (see Table 7.3).

˽

0.25 to 1 second – Sends data every 0.25 to 1 second.

˽

1 second – Sends data every second.

˽

Switch – Sends data every time the push-button is pressed.