CHAPTER 11 • CLICK 514 125
While in Logging mode, each time a SmartSensor HD detection is pushed to the Click 514
you should see the yellow 1 LED light up (left-side of yellow LED bank). You will also see
the data light on the front of the DataBridge flicker.
When you are ready to retrieve your data, simply remove the compact flash card from the
DataBridge and transfer the log files to your computer using a compact flash reader. The
data files are in a tabular format that imports easily into programs like Notepad and Excel.
Figure 11.6 – Data in Notepad
The above figure presents the data using Notepad, and the columns are as follows:
˽
Date
˽
Timestamp of event (YYYY:MM:DD,hh:mm.ss.fff)
˽
Lane of event (closest lane = 1)
˽
Speed of event (mph or kph depending upon SmartSensor HD units)
˽
Length of event (feet or meters depending upon SmartSensor HD units)
˽
Range of event (feet or meters depending upon SmartSensor HD units)
˽
Class of event
˽
Duration of event
In Excel this same data file will look like the spreadsheet shown in Figure 11.7.
Note
You must use the Format > Cells dialog box to format the cells in column B using a
custom type with the format string “h.mm.ss.000”.