beautypg.com

Configuration features, Warning – Wavetronix Click 500 (programmable controller) (CLK-500) - User Guide User Manual

Page 121

background image

120

CHAPTER 11 CLICK 514

Warning

The sixth switch of DIP switch 1 controls the mode of the device. Make sure that this
switch is in the OFF position. If it gets turned on, the device will enter Program mode
and all of the faceplate LEDs will turn off when a serial connection is made. To exit
Program mode, power will need to be cycled on the device.

Configuration Features

There are three banks of LEDs located on the front of the Click 514.

The yellow and red banks of LEDs display submenu selections and application information.

See the Operating Modes section of this chapter for more information.

The system LEDs (multicolored bank in the middle of the module) have dual functions:

they are activity indicators, reporting system status information, and they are also used in

selecting operation modes from the main menu.

Sub Menu 1

Sub Menu 2

Main Menu

Push-button

Yellow LEDs

Red LEDs

Multicolored LEDs

Figure 11.3 – Click 514 LEDs

The blue LED does not have an activity-indicating function. The other three LEDs indicate

system status as follows:

˽

PWR (red) lights up when the device has power.

˽

TD (green) lights up when the device is transmitting data.

˽

RD (yellow) lights up when the device is receiving data.

If the Click 514 receives data via one port, it will forward (transmit) the data to other con-