beautypg.com

Physical features, Communication ports – Wavetronix Click 500 (programmable controller) (CLK-500) - User Guide User Manual

Page 103

background image

102

CHAPTER 10 CLICK 513

The Click 513 compares the detected interval data to a set of predetermined speed, volume

and occupancy threshold values and activates a digital output when the data exceeds these

threshold values.

A possible application for the Click 513 is to alert traffic control operators of a congest-

ed exit ramp. If the interval data polled from the SmartSensor HD exceeds the threshold

value(s), the Click 513 will send an alert so that adjustments can be made to help clear the

congested roadway, such as keeping the traffic light green so cars can clear the exit ramp, or

displaying a message for drivers on a dynamaic message sign (DMS).

The Click 513 utilizes the Click Supervisor software for user configuration of vehicle speed,

volume and occupancy thresholds. Communication between the Click 513 and Click Su-

pervisor is easy to set up and use.

Physical Features

The Click 513 is based upon the Click 500 platform, so it has the same physical features as

the Click 500. The physical features are used for easy installation and configuration.

Figure 10.2 – Diagram of the Click 513

Communication Ports

The Click 513 has four communication ports: