CHAPTER 6 • CLICK 500

47

When the O1+ and O1- pins are connected to each other, the interface is closed and desig-

nated by a logical 1; when the O1+ and O1- pin are NOT connected, the interface is open

and designated by a logical 0. This also applies to O2+ and O2- pins on the second digital

output port (see Figure 6.8).

O1+

O1-

O2+

O2-

Digital Output

Connector

Figure 6.8 – Digital Output Connector

Digital Inputs

The digital inputs are multi-function inputs that provide the ability to read the following:

˽

Low-level AC input

˽

DC input

˽

Contact closure input

To configure the digital inputs, use switches 1–5 of DIP switches 1 and 2 on the side panel.

Switch 1 is used to configure digital input 1 and switch 2 is used to configure digital input

2. The left-side panel gives a shorthand description of the function of each of these switches

(see Table 6.2 and Table 6.3).