104

CHAPTER 10 CLICK 513

O1+

O1-

O2+

O2-

Digital Output

Connector

I1+

I1-

I2+

I2-

Digital Input

Connector

Figure 10.3 – Digital Connectors

In the standard Click513 application, these ports have the following functions:

˽

Digital output port 1 – Used to connect to contact closure device, DMS or other digital

I/O systems. This is the default output for approach 1.

˽

Digital output port 2 – For use with multiple Click 513 devices connected to one DMS.

This is the default output for approach 2.

˽

Digital input port 1 – For use with multiple Click 513 devices connected to one DMS.

˽

Digital input port 2 – For use with multiple Click 513 devices connected to one DMS.

Not used in the standard Click 513 application.

The Click 513 also has two DIP switches on the left side of the module for programming

or reprogramming the unit. For all standard Click 513 applications, the rest of the DIP

switches are unused.

Warning

The sixth switch of DIP switch 1 controls the mode of the device. Make sure that this
switch is in the OFF position. If it gets turned on, the device will enter Program mode
and all of the faceplate LEDs will turn off when a serial connection is made. To exit
Program mode, power will need to be cycled on the device.

Configuration Features

There are three banks of LEDs located on the front of the Click 513.

The yellow and red banks of LEDs display submenu selections and application information.

See the Operating Modes section of this chapter for more information.

The system LEDs (multicolored bank in the middle of the module) have dual functions:

they are activity indicators, reporting system status information, and they are also used in

selecting operation modes from the main menu.