beautypg.com

Low-level digital ac input – Wavetronix Click 500 (programmable controller) (CLK-500) - User Guide User Manual

Page 49

background image

48

CHAPTER 6 CLICK 500

I1+

I1-

I2+

I2-

Digital Input

Connector

Figure 6.9 – Digital Inputs

Digital Input 1

SW1:1

SW1:2

SW1:3

SW1:4 SW1:5

SW1:6

Low-level AC Input

On

Off

Off

Off

Off

Contact Closure Input

Off

On

Off

Off

Off

DC Input 9 VDC Threshold

Off

Off

On

Off

Off

DC Input 11.9 VDC Threshold

Off

Off

Off

On

Off

DC Input 23.8 VDC Threshold

Off

Off

Off

Off

On

Table 6.2 – Digital Input 1

Digital Input 2

SW2:1

SW2:2 SW2:3 SW2:4 SW2:5 SW1:6

Low-level AC Input

On

Off

Off

Off

Off

Contact Closure Input

Off

On

Off

Off

Off

DC Input 9 VDC Threshold

Off

Off

On

Off

Off

DC Input 11.9 VDC Threshold

Off

Off

Off

On

Off

DC Input 23.8 VDC Threshold

Off

Off

Off

Off

On

Table 6.3 – Digital Input 2

It is possible to have digital input 1 configured as one type of input and digital input 2 con-

figured as another. For example, digital input 1 could monitor low-level AC, while digital

input 2 could monitor DC voltage.

Low-level Digital AC Input

The low-level AC input is designed to work with a CR Magnetics 3110 Split-Core Current

Transformer or equivalent (two are included in the development kit). These clamp-on style