Low-level digital ac input – Wavetronix Click 500 (programmable controller) (CLK-500) - User Guide User Manual
Page 49
48
CHAPTER 6 • CLICK 500
I1+
I1-
I2+
I2-
Digital Input
Connector
Figure 6.9 – Digital Inputs
Digital Input 1
SW1:1
SW1:2
SW1:3
SW1:4 SW1:5
SW1:6
Low-level AC Input
On
Off
Off
Off
Off
–
Contact Closure Input
Off
On
Off
Off
Off
–
DC Input 9 VDC Threshold
Off
Off
On
Off
Off
–
DC Input 11.9 VDC Threshold
Off
Off
Off
On
Off
–
DC Input 23.8 VDC Threshold
Off
Off
Off
Off
On
–
Table 6.2 – Digital Input 1
Digital Input 2
SW2:1
SW2:2 SW2:3 SW2:4 SW2:5 SW1:6
Low-level AC Input
On
Off
Off
Off
Off
–
Contact Closure Input
Off
On
Off
Off
Off
–
DC Input 9 VDC Threshold
Off
Off
On
Off
Off
–
DC Input 11.9 VDC Threshold
Off
Off
Off
On
Off
–
DC Input 23.8 VDC Threshold
Off
Off
Off
Off
On
–
Table 6.3 – Digital Input 2
It is possible to have digital input 1 configured as one type of input and digital input 2 con-
figured as another. For example, digital input 1 could monitor low-level AC, while digital
input 2 could monitor DC voltage.
Low-level Digital AC Input
The low-level AC input is designed to work with a CR Magnetics 3110 Split-Core Current
Transformer or equivalent (two are included in the development kit). These clamp-on style