beautypg.com

The gateway does not power up, 1 the gateway does not power up – Comtech EF Data DTMX5000 SpectraCast User Manual

Page 126

background image

Troubleshooting

DTMX5000 IP Gateway

5–2

Rev. 1

5.1.1

The Gateway Does Not Power Up

Possible Cause

Solution

The power cord is loose, faulty or not
connected to the Gateway.

Check that the power cord is properly connected to the
Gateway and the power outlet.

Power outlet is faulty.

Check outlet or utilize another outlet.

If problem remains, the Gateway may be
faulty

Contact EFData Customer Support department.

5.1.2

No Communication Between the Gateway and the Local
Terminal

Possible Cause

Solution

Faulty terminal cable.

Use a continuity test to verify the terminal cable functioning.
Pins 2 and 3 should be crossed and Pin 5 should be connected
between both sides. If OK, utilize a different cable.

Incorrect terminal settings.

Check terminal settings and change if necessary.

5.1.3

The Gateway Does Not Reply to Ping from the Control and
Management Interface

Possible Cause

Solution

Incorrect IP address setting for the
Control and Management interface.

Check the IP address setting and change if necessary.

Incorrect Ethernet cable connection.

Ensure that the Control and Management NIC cable is
connected to the correct Ethernet port.

5.1.4

The Gateway Does Not Reply to Ping from the Transportation
Interface

Possible Cause

Solution

This is normal before connecting the
Transportation NIC.

5.1.5

Gateway Statistics Tables Indicate that there is No Data Flow to
Users

Possible Cause

Solution

Incorrect Transportation NIC IP address
setting.

Check that the transportation NIC IP address is correctly
specified and change if necessary.

The Transportation NIC is disabled.

Enable the transportation NIC.

The Transportation NIC is not connected
to the network.

Check the connection between the server and the
Transportation NIC by using Ping and ARP.