Comtech EF Data DM240XR User Manual
Page 99
![background image](https://www.manualsdir.com/files/778776/content/doc099.png)
DM240XR High-Speed Digital Modulator
SNMP
MN-DM240XR– Revision 13
8–5
g703E3(4),
g703T3(5),
sts1(6),
hssi(7),
parallelDVB(8),
parallelM2P(9),
none(10),
directv(11),
oc3(13),
stm1(14),
g703E2(15),
g703T2Bal(16),
g703T2Unbal(17),
g703E1Bal(18),
g703E1Unbal(19),
g703T1AMI(20),
g703T1B8ZS(21),
gigEthernet(22)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the various interface types.
The following choices are not supported:
none(10),
oc3(13),
stm1(14)
Note: Selecting interface types Parallel DVB,
Parallel M2P, Serial, DirecTv or HSSI will force the
outclock selection to SCT. Selecting interface type
ASI Norm or ASI Null causes the outclock selection to
be forced to None.
"
::= { radSNMPModNVStatus 14 }
radClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
inverted(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects clock polarity for Tx terrestrial clock
relative to Tx data."
::= { radSNMPModNVStatus 15 }
radDataPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
inverted(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects data polarity"
::= { radSNMPModNVStatus 16}
radSpectrum OBJECT-TYPE
SYNTAX INTEGER {
inverted(0),
normal(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Inverts the symbol mapping direction of rotation."
::= { radSNMPModNVStatus 17 }
radModulationType OBJECT-TYPE
SYNTAX INTEGER {
qpsk(0),
bpsk(1),
psk8(2),