Comtech EF Data DM240XR User Manual
Page 101
DM240XR High-Speed Digital Modulator
SNMP
MN-DM240XR– Revision 13
8–7
STATUS optional
DESCRIPTION
"unsupported"
::= { radSNMPModNVStatus 24 }
radMajorAlarmMask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Major Alarm mask:
A bit field. 0 = MASKED, 1 = UNMASKED
Bit 0 = Stream
Bit 1 = Oversample Clock PLL Lock
Bit 2 = FPGA Configuration Error
Bit 3 = Synthesis Clock PLL Lock
Bit 4 = External Reference PLL Lock
Bit 5 = Composite PLL Lock
Bit 6 = Symbol PLL Lock
Bit 7 = Invalid Terrestrial Interface
"
::= { radSNMPModNVStatus 25 }
radMinorAlarmMask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Minor Alarm mask:
A bit field. 0 = MASKED, 1 = UNMASKED
Bit 0 = Terr Ethernet data activity detect
Bit 1 = Terrestrial clock activity detect
Bit 2 = Tx data activity detect
Bit 3 = FIFO overflow/underflow error
Bit 4 = Output Level
Bit 5 = Loss of frame synchronization
Bit 6 = Terr Ethernet jitter buffer underflow
Bit 7 = Terr Ethernet jitter buffer overflow
"
::= { radSNMPModNVStatus 26 }
radCommonAlarmMask OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS current
DESCRIPTION
"Common Alarm mask:
A bit field. 0 = MASKED, 1 = UNMASKED
Bit 0 = -12V alarm.
Bit 1 = +12V alarm.
Bit 2 = +5V alarm.
"
::= { radSNMPModNVStatus 27 }
radOperatingMode OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
testPattern2to15Minus1(1),
testPattern2to23Minus1(23)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Test Pattern Operating Mode:
None,
(2^15)-1,
(2^23)-1
"
::= { radSNMPModNVStatus 28 }
radCarrierTest OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
cw(1),