Comtech EF Data DM240XR User Manual
Page 120

DM240XR High-Speed Digital Modulator
Remote Operations
MN-DM240XR– Revision 13
9–6
<1>
BB Scrambler
Bypass
0 = Normal, 1 = Bypass
<1>
Outer FEC
Bypass
0 = Normal, 1 = Bypass
<1>
Test Pattern
0 = None, 1 = 2
15
– 1, 23 = 2
23
-1
<1>
Last Rate
Control
0 = Symbol Rate, 1 = Data Rate, 2 = Auto
<1>
Interleaver
Bypass
0 = Bypass, 1 = Normal
<1>
PCR
Restamping
0 = Off, 1= On
<1>
Multi-PIIC
Mode
1 = Manual,
2 = Redundancy
<1>
Redundancy
Mode
0 = Force Prime,
1 = Force Backup,
2 = Manual Revert,
3 = Auto-Revert
<1>
Prime PIIC Slot
1 – 3
<1>
Backup PIIC
Slot
1 – 3
<1>
Pilot Symbols
0 = Off, 1= On
<1>
Inner FEC
Bypass
0 = Normal, 1 = Bypass
<1>
PL Scrambler
Bypass
0 = Normal, 1 = Bypass
<1>
Reserved
Set to 0
<1>
Reserved
Set to 1
<2>
Reserved
Set to 0
<4>
Gold Code Seq
Index
0 to 262142
<1>
Sat Framing
3=DVB-S, 5=DTV, 10=DVB-S2 Normal, 15=DVB-S2 Short
<1>
Auto EQ
Enable
0=Off, 1=On
<9>
Auto EQ Filter
Coef Name
8-character NULL terminated string, this is the filter’s name
as shown on the front panel (identical to the filter’s base
filename, the extension is assumed to be “AEQ”)
Status Bytes
<1>
Reserved
<1>
Reserved