DM240XR High-Speed Digital Modulator

TCP/IP Ethernet Setup

MN-DM240XR– Revision 13

B–3

set to a foreign address. Broadcast and loop back addresses will not be allowed. Router not used
example: Router IP Address setting: 010.000.001.001.

8. MODEM EADDR

: This displays the Modem (Unit) Ethernet Address. The Modem Ethernet

Address is configured at the factory. It is a unique Radyne equipment identifier Address.
Example: 0010650903EB

9. ETHER RATE

B.3

Network Configuration Summary

: This displays the current Ethernet port data rate. If multiple rates are available,

then a selection can be made to specify the Ethernet port data rate (10BaseT). Example Ethernet
port Data Rate: 10 MBPS/HD

If the above steps were followed and the information was entered, then the following would be
the TCP / IP configuration summary for a ‘no router specified’ setup:

1. Boot Mode =

NON-VOL

2. Bootp Server Tag =

206

3. Modem Host=

DM240

4. IP Address Mask =

255.255.0.0

5. Modem IP Address =

172.18.100.215

6. Server IP Address =

172.18.4.250

7. Router IP Address =

010.000.001.001

8. Modem Ethernet Address= 0010650903EB
9. Ethernet Rate =

10 MBPS/HD

B.4

Ethernet Test

B.4.1 Connecting the Modem Ethernet Cable to a Network Link

1. Connect the Network Switch (Hub) to the Modem Ethernet port (J9) using standard RJ-45

to RJ-45 10BaseT (CAT-5) Cables as shown below.

DM240 Ethernet Network Connection

B.4.2 Connecting the Modem Ethernet Cable Directly to a Computer (without a
Network)

The user can directly connect to the equipment without connecting to a network. This will often
occur at remote sites where a network is not available. To connect, the user will need an Ethernet
Crossover (Null) cable. The pinout for this cable is as follows,