Comtech EF Data DM240XR User Manual
Page 102
![background image](https://www.manualsdir.com/files/778776/content/doc102.png)
DM240XR High-Speed Digital Modulator
SNMP
MN-DM240XR– Revision 13
8–8
dual(2),
offset(3),
posfir(4),
negfir(5)
}
ACCESS read-write
STATUS current
DESCRIPTION
"normal, allows normal modulated data output
cw, causes the modulator to output pure carrier
dual, causes a double sideband output
offset, causes a single side band output
posfir, uses a positive FIR
negfir, uses a negative FIR"
::= { radSNMPModNVStatus 29 }
radCircuitID OBJECT-TYPE
SYNTAX RadString (SIZE (11))
ACCESS read-write
STATUS optional
DESCRIPTION
"Provides entry of Tx circuit identifier. Circuits can
be given up to 11 character alphanumeric identity such
as LINK1. Not implemented."
::= { radSNMPModNVStatus 30 }
radControlMode OBJECT-TYPE
SYNTAX INTEGER {
local(0),
terminal(1),
computer(2),
ethernet(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION
"Selects the active control source.
This is obsolete."
::= { radSNMPModNVStatus 31 }
radMode OBJECT-TYPE
SYNTAX INTEGER {
dvb(0),
direcPc(1),
direcTv(9),
dvbs2BsNbc(11),
dvbs2BsBc(12),
direcTvAmcNbc(13)
direcTvAmcBc(14),
dvbs2Nbs(15)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Selects the network specification."
::= { radSNMPModNVStatus 32 }
radInterleaver OBJECT-TYPE
SYNTAX INTEGER {
enable(0),
disable(1)
}
ACCESS read-write
STATUS current
DESCRIPTION
"Enables or disables the interleaver."
::= { radSNMPModNVStatus 33 }
radOutClockSelection OBJECT-TYPE
SYNTAX INTEGER {
scte(0),
sct(1),
none(2)
}