Comtech EF Data DM240XR User Manual
Page 133

DM240XR High-Speed Digital Modulator
Remote Operations
MN-DM240XR– Revision 13
9–19
<1>
Redundancy
Mode
0 = Force Prime,
1 = Force Backup,
2 = Manual Revert,
3 = Auto-Revert
<1>
Prime PIIC Slot
1 – 3
<1>
Backup PIIC
Slot
1 – 3
<1>
Pilot Symbols
0 = Off, 1= On
<1>
Inner FEC
Bypass
0 = Normal, 1 = Bypass
<1>
PL Scrambler
Bypass
0 = Normal, 1 = Bypass
<1>
Reserved
Set to 0
<1>
Reserved
Set to 1
<2>
Reserved
Set to 0
<4>
Gold Code Seq
Index
0 to 262142
<1>
Sat Framing
3=DVB-S, 5=DTV, 10=DVB-S2 Normal, 15=DVB-S2 Short
<1>
Auto EQ
Enable
0=Off, 1=On
<9>
Auto EQ Filter
Coef Name
8-character NULL terminated string, this is the filter’s name
as shown on the front panel (identical to the filter’s base
filename, the extension is assumed to be “AEQ”)
DM240XR Clock Source Selection Matrix
Interface Type
InClk Source
OutClk Source
RS-422 Serial
SCT or SCTE
SCT Only
G.703 (E3, T3, STS-1)
SCTE Only
SCT, SCTE, or None
HSSI
SCT or SCTE
SCT Only
OC3
SCTE Only
None
STM-1
SCTE Only
None
ASI, Advanced ASI
SCTE Only
None
M2P Parallel
SCT or SCTE
SCT Only
DVB Parallel
SCTE Only
SCT Only