Comtech EF Data DM240XR User Manual
Page 122
DM240XR High-Speed Digital Modulator
Remote Operations
MN-DM240XR– Revision 13
9–8
Bit 3 = Spare
Bit 4 = Spare
Bit 5 = Spare
Bit 6 = Spare
Bit 7 = Spare
0 = Pass, 1 = Fail
<1>
Reserve
d
<1>
+5 Voltage
Implied Decimal Point. 49 = +4.9 V
<1>
+12 Voltage
Implied Decimal Point. 121 = +12.1 V
<1>
-12 Voltage
-12 V. Implied Decimal Point and Minus Sign. 118 = -11.8 V
<2>
Reserved
TBD
<2>
Reserved
TBD
<1>
Last Rate Status 0 = Symbol Rate, 1 = Data Rate
<1>
Active PIIC Slot 1 – 3
<1>
Slot 1 PIIC Type 0x13 = ASI
<1>
Slot 2 PIIC Type 0x00 = INVALID
0x93 = ASI
0x94 = RS422 Parallel
0x95 = LVDS Parallel
0x96 = HSSI
0x9C = DirecTV (PECL)
0x9D = Ethernet
0xD3 = ASI Out (Monitor)
0xA1 = Auto EQ
0xE2 = RS422/530 Serial
0xFF = None
<1>
Slot 3 PIIC Type 0x00 = INVALID
0x93 = ASI
0x94 = RS422 Parallel
0x95 = LVDS Parallel
0x96 = HSSI
0x9C = DirecTV (PECL)
0x9D = Ethernet
0xD3 = ASI Out ( Monitor)
0xA1 = Auto EQ
0xE2 = RS422/530 Serial
0xFF = None
<1>
PIIC Clock
Activity
Bit 1 = Slot 1 Activity
Bit 2 = Slot 2 Activity
Bit 3 = Slot 3 Activity
<1>
PIIC Data Activity Bit 1 = Slot 1 Activity
Bit 2 = Slot 2 Activity
Bit 3 = Slot 3 Activity