beautypg.com

Comtech EF Data DM240XR User Manual

Page 122

background image

DM240XR High-Speed Digital Modulator

Remote Operations

MN-DM240XR– Revision 13

9–8

Bit 3 = Spare
Bit 4 = Spare
Bit 5 = Spare
Bit 6 = Spare
Bit 7 = Spare
0 = Pass, 1 = Fail

<1>

Reserve

d

<1>

+5 Voltage

Implied Decimal Point. 49 = +4.9 V

<1>

+12 Voltage

Implied Decimal Point. 121 = +12.1 V

<1>

-12 Voltage

-12 V. Implied Decimal Point and Minus Sign. 118 = -11.8 V

<2>

Reserved

TBD

<2>

Reserved

TBD

<1>

Last Rate Status 0 = Symbol Rate, 1 = Data Rate

<1>

Active PIIC Slot 1 – 3

<1>

Slot 1 PIIC Type 0x13 = ASI

<1>

Slot 2 PIIC Type 0x00 = INVALID

0x93 = ASI
0x94 = RS422 Parallel
0x95 = LVDS Parallel
0x96 = HSSI
0x9C = DirecTV (PECL)
0x9D = Ethernet
0xD3 = ASI Out (Monitor)
0xA1 = Auto EQ
0xE2 = RS422/530 Serial
0xFF = None

<1>

Slot 3 PIIC Type 0x00 = INVALID

0x93 = ASI
0x94 = RS422 Parallel
0x95 = LVDS Parallel
0x96 = HSSI
0x9C = DirecTV (PECL)
0x9D = Ethernet
0xD3 = ASI Out ( Monitor)
0xA1 = Auto EQ
0xE2 = RS422/530 Serial
0xFF = None

<1>

PIIC Clock

Activity

Bit 1 = Slot 1 Activity
Bit 2 = Slot 2 Activity
Bit 3 = Slot 3 Activity

<1>

PIIC Data Activity Bit 1 = Slot 1 Activity

Bit 2 = Slot 2 Activity
Bit 3 = Slot 3 Activity


This manual is related to the following products: