Comtech EF Data DM240XR User Manual
Page 110
DM240XR High-Speed Digital Modulator
SNMP
MN-DM240XR– Revision 13
8–16
STATUS current
DESCRIPTION
"Common Alarm latched status:
A bit field. 0 = PASS, 1 = FAIL
Bit 0 = -12V alarm.
Bit 1 = +12V alarm.
Bit 2 = +5V alarm.
"
::= { radSNMPModStatus 6 }
radRevisionNumber OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS optional
DESCRIPTION
"M&C Revision number."
::= { radSNMPModStatus 7 }
radPlus5Volts OBJECT-TYPE
SYNTAX RadVoltageLevel (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"+5V monitor with implied decimal point.
For example, a value of 51 represents +5.1 Volts."
::= { radSNMPModStatus 8 }
radPlus12Volts OBJECT-TYPE
SYNTAX RadVoltageLevel (0..255)
ACCESS read-only
STATUS current
DESCRIPTION
"+12V monitor with implied decimal point.
For example, a value of 119 represents +11.9 Volts."
::= { radSNMPModStatus 9 }
radMinus12Volts OBJECT-TYPE
SYNTAX RadVoltageLevel (-255..0)
ACCESS read-only
STATUS current
DESCRIPTION
"-12V monitor with implied decimal point.
For example, a value of -122 represents -12.2 Volts."
::= { radSNMPModStatus 10 }
radTemperature OBJECT-TYPE
SYNTAX INTEGER (0..1000)
ACCESS read-only
STATUS optional
DESCRIPTION
"Temperature monitor with implied decimal point.
For example, a value of 490 represents 49.0 C"
::= { radSNMPModStatus 11 }
radFactoryConfiguration OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION
"A bit field that shows the factory configuration
options. 0=No, 1=Yes.
Bit 0 = Serial Interface Present
Bit 1 = Parallel Interface
Bit 2 = ASI Norm Interface
Bit 3 = ASI Null Interface
Bit 4 = E3 Interface Present
Bit 5 = T3 Interface Present
Bit 6 = STS-1 Interface Present
Bit 7 = HSSI Interface Present
Bit 8 = DSS Option Enabled
Bit 9 = SNMP Option Enabled
Bit 10 = Parallel DVB Present
Bit 11 = Parallel M2P Present
Bit 12 = DVB LVDS Present