<1>

Spectrum

0 = Inverted, 1 = Normal

<1>

Reserved

TBD, 0 = Default

<1>

Tx Interface

Type

0 = Serial,
1 = Parallel,
2 = ASI,
3 = Advanced ASI,
4 = G.703E3,
5 = G.703T3,
6 = G.703STS-1,
7 = HSSI,
8 = Parallel DVB,
9 = Parallel M2P,
10 = None,
13 = OC3,
14 = STM-1,
15 = G.703E2,
16 = G.703T2Bal,
17 = G.703T2Unbal,
18 = G.703E1Bal,
19 = G.703E1Unbal,
20 = G.703T1AMI
21 = G.703T1B8ZS
22 = Ethernet
(See table at the end of this command.)

<1>

Input Clock

Polarity

0 = Normal, 1 = Inverted

<1>

Data Polarity

0 = Normal, 1 = Inverted

<1>

Input Clock

Source

0 = SCTE, 1 = SCT

<1>

Reserved

TBD, Default = 0

<11>

Reserved

TBD

<1>

Reserved

TBD

<1>

Major Alarm

Mask

Bit 0 = Spare
Bit 1 = Transmit Oversample PLL Lock
Bit 2 = FPGA Config Error
Bit 3 = IF Synthesizer PLL Lock
Bit 4 = External Reference PLL Lock
Bit 5 = Composite PLL Lock
Bit 6 = Symbol PLL Lock
Bit 7 = Spare
0 = Mask, 1 = Allow

<1>

Minor Alarm

Mask

Bit 0 = Terrestrial Ethernet data activity detect

Bit 1 = Loss Terrestrial Clock
Bit 2 = Loss Terrestrial Data
Bit 3 = FIFO Error

Bit 4 = Output Level

Bit 5 = Terrestrial Framing Error