beautypg.com

Comtech EF Data DM240XR User Manual

Page 130

background image

DM240XR High-Speed Digital Modulator

Remote Operations

MN-DM240XR– Revision 13

9–16


Opcode: <2B54h>

Command Pilot Symbols

<1>

Pilot Symbols

0=Off, 1=On



Opcode: <2560h>

Query RF Switch Status

<1>

Redundancy

Mode

3 = auto-revert, 4 = manual, 5 = backup

<1>

Fault Test

0 = normal, 1 = faulted

<1>

Switch

Connector

0 = backup, 1 = prime

<1>

Online Side

0 = backup, 1 = prime

<1>

Distant Status

0 = normal, 1 = faulted


Opcode: <2601h>

Command a Modulator's Configuration

<4>

IF

Frequency

Binary Value, units Hz in 1Hz steps.
50000000Hz to 180000000Hz 70/140
950000000Hz to 2050000000Hz L-Band

<2>

Reserved

TBD

<4>

Data Rate

Binary Value, 1 bps Steps (See note at the end of this
command.)

<4>

External

Reference

Binary Value, units Hz in 8000Hz steps, e.g. 1000000Hz,
1008000Hz, etc.
256000Hz to 10000000Hz

<1>

Frequency

Reference

Source

0 = Internal, 1 = External

<1>

Modulation

Type

0 = QPSK, 1 = BPSK, 2 = 8PSK, 3 = 16QAM, 9 =

16APSK, 10 = 32APSK (See note at the end of this
command.)

<1>

Inner FEC Rate

1 = 1/2 Rate, 2 = 2/3 Rate, 3 = 3/4 Rate, 4 = 5/6 Rate, 5 = 7/8
Rate, 6 = 6/7 Rate, 7=4/5, 8 = 8/9 Rate, 9 = 9/10 Rate, 128 =
1/4 Rate, 129 = 1/3 Rate, 130 = 2/5 Rate, 131 = 3/5 Rate (See
note at the end of this command.)

<1>

Reserved

TBD, Default = 1

<1>

Reserved

TBD, Default = 1

<1>

Reserved

TBD, Default = 0

<1>

Reserved

TBD, Default = 0

<2>

Transmit Power

Level

Signed Value. 0 to –250 (0.0 to –25.0 dBm)

<1>

Carrier Control

0 = Off, 1 = On

<1>

Carrier Type

0 = Normal, 1 = CW, 2 = Dual, 3 = Offset, 4 = Pos FIR, 5 =
Neg FIR