INTERFACE TYPE:

{ASI/Advanced ASI, HSSI, M2P Parallel, DVB Parallel
(RS422 or LVDS), RS530/RS422 Serial, Ethernet 100/1000
Base-T, Direct TV PECL}


Enter the Terrestrial Interface type.

Only the Interface types that are installed may be selected. The Ethernet

Interface will add additional menus that are identified in section 4.2.3.2



TERR FRAMING:

DVB-S:

{DVB 188, DVB 204, NONE}

Terrestrial framing for DVB-S allows the user to choose framing
packet.

DVB-S2: {DVB 188, DVB 204, NONE}
DVB-S2L {CCM uses DVB 188 or NONE}
DVB-S2: {ACM uses DVB 204}
DTV

{DIRECTV}


DATA POLARITY

{NORMAL, INVERTED}
Allows the data to be used as is or to be inverted.


INCLK SRC

{SCTE, SCT}
Input Clock Source – Allows the user to choose between an
internal (SCT) and external (SCTE) clock sources.


INCLK POL

{NORMAL, INVERTED}
Input Clock Polarity – Allows the user to use the input clock
signal as is or to invert it.


OUTCLK SRC

{“Status Only”}
When used with G.703, the user may choose between an internal
(SCT), external (SCTE), or no output clock sources. All else
provides status only.

OUTCLK POL

{NORMAL, INVERTED}
Output Clock Polarity – Allows the user to use the output clock
signal as is or to invert it.


REF FREQ SRC:

{Internal, External}
Reference Frequency Source – Allows the user to select either an
internal or external reference source.


EXT REF ( MHz):

External Reference Frequency:
Enter the External Reference Frequency in 8 kHz steps from
0.256 MHz to 10 MHz.