beautypg.com

Comtech EF Data DM240XR User Manual

Page 138

background image

DM240XR High-Speed Digital Modulator

Remote Operations

MN-DM240XR– Revision 13

9–24


Opcode: <2C05h>

Command Set Date

<1>

Year

00 – 99

<1>

Month

1 – 12

<1>

Day

1 – 31


Opcode: <2C06h>

Command Set Time and Date

<1>

Year

00 – 99

<1>

Month

1 – 12

<1>

Day

1 – 31

<1>

Hour

0 – 23

<1>

Minute

0 – 59

<1>

Second

0 – 59

Opcode: <2F40h>

Command RF Redundancy Mode

<1>

Redundancy

Mode

3 = auto-revert, 4 = manual, 5 = backup


Opcode: <2F41h >

Command RF Fault Test

<1>

Fault Test

0 = normal, 1 = faulted


Opcode: <2F42h >

Command RF Activate Side

<1>

Activate Side

0 = backup, 1 = prime

This manual is related to the following products: