CDD-562AL/564A/L Multi-Channel Demodulator

Revision 0

Quick Start Guide

MN-CDD562AL564AL

8–7

8.7.5 Steps to set the IP Stack 3xDES Select Key to ClearRoute Table

8.7.5.1

Do these steps for Satellite Modem CDM-IP 1:

1. From the CLI Main Menu, type R to go to the Route Table submenu.
2. Enter 1 to configure the first route.
3. Enter a meaningful name (e.g., ‘test’).
4. Set the IP Address to 172.17.10.0
5. Set the Number of Subnet Bits to 24
6. Select S for Interface to which the route is destined,
7. Type E to go to Per Route.
8. Select No to disable each of these options: HdrCompression and PayloadCompression.
9. Select Clear to disable 3xDES.

8.7.5.2

Do these steps for Satellite Modem (CDM-IP) 2:

10. From the CLI Main Menu, type R to go to the Route Table submenu.
11. Enter 1 to configure the first route.
12. Enter a meaningful name (e.g., ‘test’)
13. Set the IP Address to 172.16.10.0
14. Set the Number of Subnet Bits to 24
15. Select S for Interface to which route is destined to .
16. Type E to go to Per Route.
17. Select No to disable each of these options: HdrCompression and PayloadCompression.
18. Select Clear to disable 3xDES.

8.7.5.3

Do these steps on the CDD-564A/L Demodulator 3:

19. From the CLI Main Menu, type R to go to the Route Table submenu.
20. Enter 1 to configure the first route.
21. Enter a meaningful name (e.g., ‘ToCDMIP2’).
22. Set the IP Address to 172.17.10.0
23. Set the Number of Subnet Bits to 24
24. Set the Next-hop IP Address to 172.16.10.1

For this example, the CDD-564A/L Demodulator 3 Route Table shows this data:

Route Name

Dest IP/SNet Bits

Next Hop

MultiCast State

Route001...[ToCDMIP2 172.17.10.0/24 172.16.10.1 N/A toEth]..1

25. If the Header Decompression Feature is available on this demodulator, do these steps:

a. From the CLI Main Menu, type A to go to the Administration submenu.
b. From the Administration submenu, type F to go to the Features Configuration submenu.
c. From the Features Configuration submenu, type H to select RxHeaderCompression.
d. Type 1 to disable Header Decompression on Demod 1.