beautypg.com

1 dc operation – applying power – Comtech EF Data CDD-562AL User Manual

Page 53

background image

CDD-562AL/564A/L Multi-Channel Demodulator

Revision 0

Rear Panel Connections

MN-CDD562AL564AL

3–9

3.3.3

48V Direct Current (DC) Power Interface (Optional)

1 Plug-in Power Receptacle

Figure 3-5. CDD-56xA/L DC Power Interface

DC Power Specifications

Input Power

48 W (typical)

106 W (maximum)

Input Voltage

48 V DC nominal

(36 V to 60 V)

Connector Type

Corcom PS series

Mating Connector

Corcom GA210 or Molex 03-12-1026

Fuse Protection

Line and Neutral Fusing

(2X) 5mm x 20mm Slow-blow type fuses:

T4A (4 Amp)

3.3.3.1 DC Operation – Applying Power

Figure 3-6. Applying DC Power to the CDD-56xA/L

To apply DC power to the CDD-56xA/L:

1. Assemble the user-supplied red (+) and black (–) DC power leads and their crimped terminals

into the shell of the module mating connector.

a. Number 18 AWG minimum wires are recommended.

b. Note the keyed orientation for the wires.

2. Connect the user-supplied DC power leads to the power source.

3. Plug the connector into the keyed module socket as shown.