beautypg.com

2 ac operation – replacing fuses – Comtech EF Data CDD-562AL User Manual

Page 52

background image

CDD-562AL/564A/L Multi-Channel Demodulator

Revision 0

Rear Panel Connections

MN-CDD562AL564AL

3–8

3.3.2.2 AC Operation – Replacing Fuses

The CDD-56xA/L uses two 5mm x 20mm Slow-blow fuses – one each for line and neutral connections.
The fuses are contained within a fuse holder that is press-fit into the body of the IEC power module
(located on the rear panel, Figure 3-4).

Figure 3-4. Replacing CDD-56xA/L AC Fuses

WARNING
Disconnect the power supply first.

To replace the fuse(s):

1. Disconnect the power supply.

2. Unseat the fuse holder from the IEC power module.

a. Use the slot to pry the holder outward from the IEC power module.

b. Pull the holder straight out, and then swing the holder away from the module.

3. Remove and replace the T2 (2.00 Amp) fuses as needed.

4. Re-seat the fuse holder in the IEC power module.

CAUTION
For continued operator safety, always replace the fuses with the correct type and rating.
See Table 3-2.

Table 3-2 Correct Fuses

Model

Input

Power Consumption

Fuse

CDD-564A

AC

100-240VAC, 50-60HZ, 0.62-0.26A 1A

CDD-564AL

AC

100-240VAC, 50-60HZ, 1.24-0.52A 2A

CDD-562AL

AC

100-240VAC, 50-60HZ, 0.75-0.31A 1A

CDD-564A

DC

43-60VDC, 1.43-1.1A

2A

CDD-564AL

DC

43-60VDC, 2.9-2.1A

4A

CDD-562AL

DC

43-60VDC, 1.73-1.25A

2.5A

This manual is related to the following products: