3 lnb configuration (per lnb) screen – Comtech EF Data CDD-562AL User Manual

Page 136

background image

CDD-562AL/564A/L Multi-Channel Demodulator

Revision 0

Telnet and CLI Operation

MN-CDD562AL564AL

9–34

9.2.2.6.1.3 LNB Configuration (Per LNB) screen

Go to the LNB Configuration (Per Demod) screen from the Configuration screen.

You can set the parameters for each LNB. Use Demod Select… Z to change the demodulator before you
set the other parameters.

LNB DC Supply Voltage, keystroke: P

• Select one:

o

1 – Off

o

2 – 13 Volts

o

3 – 18 Volts

LNB 10MHz Reference Enable, keystroke: R

• Switches between [On] or [Off]:

LNB Current Alarm Lower Limit (mA), keystroke: C

Valid range is from 10 to 400 mA.

LNB Current Alarm Upper Limit (mA), keystroke: H

Valid range is from 50 to 600 mA.

LNB LO Frequency (MHz), keystroke: F

Valid range is from 0 to 65000 MHz. Enter 0 to disable.

LNB Voltage, keystroke: none, read-only

Shows active LNB voltage values for the selected LNB, if an LNB is detected.

LNB Current, keystroke: none, read-only

Shows active LNB current values for the selected LNB, if an LNB is detected.