C.4.1 steps to set the active router working mode, C.4.2 ip address requirements – Comtech EF Data CDD-562AL User Manual
Page 236

CDD-562AL/56xA/L Multi-Channel Demodulator
Revision 0
Dedicated Management Port
MN-CDD562AL56xAL
C–4
C.4
Working Mode = Router Mode (Point-to-Multipoint / Point-to-Point /
Vipersat)
C.4.1 Steps to set the active Router Working Mode
1. Use the CLI to set the active Router Working Mode
2. On the Administration menu, type C to see the available choices:
•
Type 1 for Small Network, Router uses 1-byte HDLC addresses
•
Type 2 for Large Network, Router mode using 2-byte HDLC addresses
•
Type 3 for Point to Point, Router mode uses 0 HDLC addresses to save satellite bandwidth
•
Type 4 for Vipersat, Router mode when running in a Vipersat Network
3. Type S to save the change.
4. Repeat the steps in Section D.3.1 to enable Dedicated Management Port operation.
C.4.2 IP Address requirements
When Dedicated Management is disabled, the existing Management IP Address is used for both M&C
and traffic.
When used in Router Mode, Dedicated Management Port requires two IP Addresses. See Figure C-4:
• One IP Address for M&C (management) – the 10/100 Ethernet M&C port
• One IP Address for WAN (Ethernet data) traffic – the 10/100 Ethernet Traffic port
Figure C-4. CDD-564A/L Router Mode IP Addresses
When Dedicated Management Port is first enabled, the existing single IP Address is assigned
automatically as the Management IP Address.
You must set the Traffic IP Address(es).