CDD-562AL/564A/L Multi-Channel Demodulator

Revision 0

Telnet and CLI Operation

MN-CDD562AL564AL

9–42

Codecast Multicast Address, keystroke: M

• Configures the IP Multicast Address for the Codecast protocol.

o

Format aaa.bbb.ccc.ddd

o

Range for aaa: 224 through 239

• The IP Module can install the firmware updates on multiple units using the Codecast protocol.

This makes upgrading units easier in bigger networks.

PARAM Image, keystroke: C

• Identifies the PARAM file that is loaded on bootup.

o

1=Factory – Uses the internal, hard-coded factory default parameters.

o

2=PARAM – Last saved Parameter file.

Statistics, keystroke: T

• Opens the Statistics Menu.
• See Section 9.2.2.7.2.

Event Log, keystroke: E

• Opens the Event Log screen.
• See Section 9.2.2.7.3.

Database Operations, keystroke: D

• Opens the administrative Database Operations screen.
• See Section 9.2.2.7.4.

Reset, keystroke: R

• Reboots the Unit. This has the same effect as stopping and starting power for the unit.

Diagnostics, keystroke: G

• Opens the Diagnostics screen.
• See Section 9.2.2.7.5.

M&C Interface, keystroke: F

• Gives you access to the demodulator’s available remote commands and queries.
• Once the M&C Interface is selected, a Controller-to-Target remote command or query takes this

form at the ‘#’ prompt:

o

Start of Packet ‘<’

o

Address Delimiter ‘/’

o

Target Address (1-4 characters, 0001 – 0004)

o

3-character Instruction Code (e.g., RFQ)

o

Instruction Code Qualifier – Command ‘=’ or Query ‘?’

• Example: M&C CLI INTERFACE

o

(X=Exit) #<1/RFQ?