3.3.4.3.3 Fabricating an Ethernet Cable

3.3.4.3.3.1

Fabricating an ODM-840 Ethernet Cable

To  fabricate  a  field‐installable  Ethernet  cable  for  use  with  the  ODM‐840  Outdoor  Remote 
Router, use the CN/RJF‐6B connector provided in kit KT‐0000263 or KT‐0020566. 
 
Refer to Figure 3‐17 and follow these steps: 
 

Step 

Task 

Thread the user‐supplied RJ‐45 cordset (Item 1) through the Item 2 components. Be 
sure to note the order and orientation of all components prior to final assembly of 
the connector. 

Assemble the connector insulator insert halves (Item 2.4) to the RJ‐45 cordset plug: 
 

• Depress the RJ‐45 cordset plug tab and slip one half of the insulator insert 

onto the RJ‐45 plug. 
 

• Assemble the other half of the insulator insert onto the RJ‐45 plug. 

 

• Snap the insulator lock tab into place to complete the insulator assembly. 

At the front, seat the insulated RJ‐45 plug assembly into the circular connector sleeve 
(Item  2.5)  –  note  the  sleeve’s  main  key  orientation  as  shown  in  the  figure  must 
conform  to  the  Amphenal  ‘Code  A’  orientation  specification  –  and  then  thread  the 
assembly onto the connector body (Item 2.3) 

Use  the  jam  nut  (part  of  Item  2.3)  to  secure  the  circular  connector  sleeve  and 
insulated  plug  assembly  (in  its  correct  orientation)  to  the  connector  body.  DO  NOT 
OVERTIGHTEN. 

At the back, slip the compression bushing (Item 2.2) into the connector body, and 
then screw the end cap (Item 2.1) onto the connector body. DO NOT OVERTIGHTEN. 

 
 
 
 