3 field-fabricated user cabling, 1 fabricating an ac power cable, 2 fabricating a serial communication cable – Comtech EF Data ODM-840 User Manual
Page 73

ODM/R-840 Outdoor Remote Router
Revision 0
Installation
MN-ODM840
3–23
3.3.4.3 Field-Fabricated User Cabling
3.3.4.3.1 Fabricating an AC Power Cable
To fabricate a site‐specific AC power cable (for use only with ODM‐840 units), see the wire list in
Figure 3‐15. Any fabricated cable must use ITT Cannon P/N KPT06B‐12‐35 as the P1 mating
connector.
AC POWER CABLE WIRE LIST
FROM PLUG WIRE
TO P1 CONNECTOR PIN
SIGNAL DESCRIPTION
BLACK ‘A’ LINE
(L1)
WHITE ‘B’
NEUTRAL
(L2)
GREEN ‘C’
GROUND
(GND)
Figure 3-15. AC Power Cord (REF CEFD P/N CA-0000435)
3.3.4.3.2 Fabricating a Serial Communication Cable
To fabricate a site‐specific Serial Communication Cable (for use with ODM‐840 or ODMR‐840
units) see Table 2‐2 in Sect. 2.2.3.1 of Chapter 2. ODM/R CONNECTIONS for the
‘CONSOLE/REDUNDANCY’ connector pinouts. Any fabricated cable must use ITT Cannon P/N
KPT06J14‐19P (MS3116J14‐19P) as the mating connector.
SERIAL COMMUNICATION CABLE WIRE LIST
FROM
TO
SIGNAL DESCRIPTION
P1-B
J1-5
GND
P1-C J1-3
RX
EIA-232
P1-M J1-2
TX
EIA-232
Figure 3-16. Serial Communication Cable (REF CEFD P/N CA-0000722)