8 configuration | buc (block upconverter) – Comtech EF Data ODM-840 User Manual
Page 132

ODM/R-840 Outdoor Remote Router
Revision 0
Ethernet-based Remote Product Management
MN-ODM840
5–44
5.4.4.3.8
Configuration | BUC (Block Upconverter)
This page is operational only when an optional BLOCK UPCONVERTER is installed.
Use this page to configure Block Upconverter parameters, and to display the BUC status for
L‐Band operation.
Figure 6‐23. Configuration | BUC page
BUC Control
The acceptable/valid operating range for each item in this section is provided in parentheses.
• BUC LO Freq (MHz) (3000‐65000) – Enter the BUC Local Oscillator frequency in MHz.
• BUC Power Supply – Use the drop‐down menu to select the BUC Power Supply as either
Off or On.
• BUC 10 MHz Reference Enable – Use the drop‐down menu to select the BUC 10 MHz
Reference Enable as either Off or On.
• BUC Low Current Limit (mA) (0‐4000) – Enter the BUC low current alarm limit in 100mA
increments.
• BUC High Current Limit (mA) (0‐4000) – Enter the BUC high current alarm limit in 100 mA
increments.