ODM/R-840 Outdoor Remote Router

Revision 0

Ethernet-based Remote Product Management

MN-ODM840

5–50

current conditions. Note that this value must be less than the value specified for the SCPC 
Step Up Threshold. The valid range is from 0 to 100%. A typical setting for this parameter is 
65%

 
Delay – Enter the Switching Delay period, in seconds, to ensure that a premature switch up 

or down in the SCPC rate does not occur due to a temporary rise or fall in traffic. The valid 
range is from 1 to 50 seconds. 

 
Excess Capacity – Enter the Excess Capacity data rate value (percentage) to be added to the 

SCPC data rate. This setting makes additional bandwidth available for when demand arises 
while minimizing Step Up switching events. The valid range is from 0 to 100%. 

ToS Switching Configuration

Enable – Use the drop‐down menu to select operation as Disabled or Enabled

 

Max  #  of  Sessions  (per  ToS  Id)  (1‐127)  –  Allows  setting  a  limit  for  the  number  of  active 

sessions for a particular ToS switch type. Note that the overall limit for active sessions in the 
network is 127. 

 
Click [Submit] to save these settings. 
 
A ToS Rules Table is provided in this section. From left to right: 
 
Index – The automatically‐assigned specific rule internal index number is identified here. 

 

Name – Enter a text label for circuit identification. The valid range is from 1 to 20 characters. 

 

ID – Enter an integer value, in the range from 1 to 63, for the ToS ID. 

 

Type – Enter an integer value, in the range from 64 to 254, for the Switch Type to inform the 

VMS what switching policy to use. 
 

SCPC Data Rate – Enter the desired data rate, in kbps, for this service type. The valid range is 

from 16 to 16000 kbps. 
 

Timeout – Enter the timer setting for restoring home state condition when data packet flow 

stops for this duration. The valid range is from 0 to 60

 
To edit a ToS Switching Configuration rule: 
 
Edit the information for the specific indexed rule. Click [Change] when done. 
 
To delete a ToS Switching Configuration rule: 
 
Click [Delete] to delete the specific indexed rule from the ToS Rules Table. 
 

 

 