2.3.3 Alternating Current (AC) Power Interface
This interface is standard on the ODM‐840.
Mating Connector: CEFD P/N CN/MS‐STPG03F02 (ITT Cannon KPT06B‐12‐35).
Table 2-3. AC Power Pin Assignments
Pin
Description
A LINE
(L1)
B NEUTRAL
(L2)
C GND
2.3.4 Direct Current (DC) Power Interface
This interface is optional on the ODM‐840. It is standard on the ODMR‐840;
specifically, the user power interface for the ODMR‐840 is provided on the
ODMR‐PS Power Supply module (Figure 2‐5). (The ODMR‐840 is connected to
the ODMR‐PS using the Unit‐to‐Unit cable CEFD P/N CA‐0020592.)
Figure 2-5. ODMR-840 ► ODMR-PS ► User – DC Power Interface
Mating Connector: CEFD P/N CN/STPG04F01
(Glenair IPT06E‐12‐4‐SSR‐F7). (This connector is
also provided as part of Unit‐to‐User cable CEFD P/N CA‐0020696.)
Table 2-4. DC Power Pin Assignments
Pin
Description
A V+
B GND
C V-
D NO
CONNECT