Comtech EF Data ODM-840 User Manual
Page 166

ODM/R-840 Outdoor Remote Router
Revision 0
Serial-based Remote Product Management
MN-ODM840
6–10
Parameter
Type
Command
(Instruction
& Qualifier)
Number of
Arguments
Description of Arguments
Response to
Command
Query
(Instruction &
Qualifier)
Response to Query
GE Address
IG1=
18 bytes numerical Command or Query.
Sets the IP Address and network prefix for the 10/100/1000 BaseT GE Ethernet
port, in the form aaa.bbb.ccc.ddd/yy, where:
(Permitted ranges – cannot all be zero)
aaa = 0-223
bbb = 0-255
ccc = 0-255
ddd = 0-255
yy = network prefix (range: 8 to 31)
Other restrictions:
If aaa>191, prefix may not be less than 24.
If aaa>127, prefix may not be less than 16.
Example: IG1=010.006.030.001/24
IG1=
IG1?
IG1*
IG1#
IG1?
IG1=xxx.xxx.xxx.xxx/yy
(see Description of
Arguments)
Management IP
Address
IPA=
18 bytes numerical Command or Query.
Sets the IP Address and network prefix for the 10/100 Base T Ethernet
management port, in the form aaa.bbb.ccc.ddd/yy, where:
(Permitted ranges – cannot all be zero)
aaa = 0-223
bbb = 0-255
ccc = 0-255
ddd = 0-255
yy = network prefix (range: 8 to 31)
Example: IPA=010.006.030.001/24
IPA=
IPA?
IPA*
IPA#
IPA?
IPA=xxx.xxx.xxx.xxx/yy
(see Description of
Arguments)
GE Link
Configuration
LC1=
1 byte, value 0 thru
5
Command or Query.
GE Interface mode, where:
0=Auto Negotiate
1=1000Mbps -Full Duplex
2=100Mbps – Full Duplex
3=100Mbps – Half Duplex
4=10Mbps – Full Duplex
5=10Mbps – Half Duplex
LC1=
LC1?
LC1*
LC1#
LC1?
LC1=x
(see Description of
Arguments)
Management
MAC Address
N/A
12 bytes, alpha-
numerical
Query only.
Returns the unique MAC Address for the router.
Example: MAC=0006B00001C2
N/A
MAC?
MAC=aabbccddeeff
(see Description of
Arguments)
GE MAC
Address
N/A
12 bytes, alpha-
numerical
Query only.
Returns the unique GE MAC Address.
Example: MG1=0006B00001C2
N/A
MG1?
MG1=aabbccddeeff
(see Description of
Arguments)