ODM/R-840 Outdoor Remote Router

Revision 0

Ethernet-based Remote Product Management

MN-ODM840

5–45

Set the desired BUC configurations. Click [Submit BUC Control] to save. 

BUC Status

BUC Power Supply, BUC Voltage (V), and BUC Current (mA) – When the presence of BUC Power 
Supply  is  detected,  it  is  acknowledged  here  and  its  voltage  and  current  information  is 
continuously monitored and is provided on a read‐only basis. 
 
Click [Refresh] to update this section with its latest available statistics. 

5.4.4.3.9

Configuration | LNB (Low Noise Block Downconverter)

 

This  page  is  operational  only  when  an  optional  LOW‐NOISE  BLOCK  DOWNCONVERTER  is 
installed.
 

 
Use this page to configure Low‐Noise Block Downconverter parameters, and to display the LNB 
status for L‐Band operation. 
 

Figure 6‐24. Configuration | LNB page 

LNB Control

The acceptable/valid operating range for each item in this section is provided in parentheses. 
 
LNB Frequency (3000‐65000) – Enter a value (in MHz) for the LNB Frequency. 

 

Rx LO Frequency – Use the drop‐down menu to designate the Rx Local Oscillator Frequency 

as a HIGH (+) or LOW (‐) limit.  

 