beautypg.com

1 configuration | interface | e1 | configuration – Comtech EF Data ODM-840 User Manual

Page 109

background image

ODM/R-840 Outdoor Remote Router

Revision 0

Ethernet-based Remote Product Management

MN-ODM840

5–21

5.4.4.3.1.2

Configuration | Interface | E1 pages (ODM-840 only)

 

1. E1 Interface operation is not available with the ODMR‐840 Reduced Form Factor 

Outdoor Remote Router.  
 

2. These pages are operable only when the ‘G.703 E1 Interface / RAN Optimization’ 

FAST and hardware options are installed and activated. 

Appendix C. WAN/RAN OPTIMIZATION 

 
Click the Configuration or Time Slots tab to continue.  

5.4.4.3.1.2.1 Configuration | Interface | E1 | Configuration

 
 

Figure 6‐10. Configuration | Interface | E1 | Configuration page 

E1 Configuration

Line Type – Use the drop‐down menu to select this parameter as Framed, Framed‐CRC, or 

Unframed
 

This manual is related to the following products: