1 configuration | interface | e1 | configuration – Comtech EF Data ODM-840 User Manual
Page 109
ODM/R-840 Outdoor Remote Router
Revision 0
Ethernet-based Remote Product Management
MN-ODM840
5–21
5.4.4.3.1.2
Configuration | Interface | E1 pages (ODM-840 only)
1. E1 Interface operation is not available with the ODMR‐840 Reduced Form Factor
Outdoor Remote Router.
2. These pages are operable only when the ‘G.703 E1 Interface / RAN Optimization’
FAST and hardware options are installed and activated.
Appendix C. WAN/RAN OPTIMIZATION
Click the Configuration or Time Slots tab to continue.
5.4.4.3.1.2.1 Configuration | Interface | E1 | Configuration
Figure 6‐10. Configuration | Interface | E1 | Configuration page
E1 Configuration
• Line Type – Use the drop‐down menu to select this parameter as Framed, Framed‐CRC, or
Unframed.