Comtech EF Data ODM-840 User Manual
Page 154

ODM/R-840 Outdoor Remote Router
Revision 0
Ethernet-based Remote Product Management
MN-ODM840
5–66
• To load (recall) a configuration set: Use the bottom (Load) Select Location dropdown to
first select 1 through 10, and then click [Load Configuration] to recall the selected
configuration settings.
BERT Config
(Where BERT is the acronym for Bit Error Rate Test) Use the drop‐down menus to:
• Configure the Tx or Rx BERT State as On or Off.
• Configure the Tx or Rx BERT Pattern as 2^23‐1 (2
23
‐1) or 2047.
• Set Error Insertion as either Off or 10E‐3.
Select the desired BERT settings in this section. Click [Submit] to save the settings and execute
the test.
BERT Monitor
This section displays the ongoing BERT. Click [Restart] to restart the BERT Monitor. Otherwise,
click [Update] to refresh a test already in progress.
The ODM/R‐840 will not accept IP traffic while a BERT is in progress.
Redundancy
If the unit is part of a 1:1 or 1:N redundant pair of ODM/R‐840s, and this unit is currently online,
click [Force Redundancy Switch] to cause the unit to switch to standby.
Console Configuration
Use the drop‐down menu to select the desired communications protocol for the unit
‘CONSOLE/REDUNDANCY’ port. The available selections are:
o
RS232-8N1-38400
o
RS485-8N1-38400
o
RS485-8N1-9600
o
RS485-8N1-57600
o
RS485-8N1-19200
o
RS485-8N1-115200
Click [Submit] to save these settings.