background image

ODM/R-840 Outdoor Remote Router

Revision 0

Ethernet-based Remote Product Management

MN-ODM840

5–30

o

VersaFEC MODCOD 4 – QPSK 0.803

o

VersaFEC MODCOD 10 – 16-QAM 0.829

o

VersaFEC MODCOD 5 – 8-QAM 0.642

o

VersaFEC MODCOD 11 – 16-QAM 0.853

Target  Es/No  Margin  –  Use  the  drop‐down  menu  to  select  a  margin  value,  in  0.5  dB 

increments, from 0.0 to 4.5 dB.  
 

 

The ACM system is designed to switch based on thresholds that correspond 
to a BER of 5 x 10

‐8

 for each MODCOD. However, in order to prevent oscillation 

around two MODCODs at this exact value, 0.3 dB of hysteresis has been added. 

 
Click [Submit] to save these setting changes. 

Tx ACM Status (read-only)

Information is presented in this section as follows:  
 
Seconds since last LQRM –  Amount of time in seconds since an LQRM (Link Quality Report 

Message) message was received. 
 

Max Seconds since last LQRM – Maximum amount of time since last LQRM message was 

received. 

 
Last Reported Es/No –  EsNo value received in the last LQRM message. 

 

Current MODCOD –  Currently selected MODCOD. 
 
Current DataRate –  Current data rate based on current symbol rate and MODCOD. 
 

Tx ACM Events (read-only)

In addition to the date‐ and time‐stamp assigned for each event, information is presented in this 
section as follows: 
 
Reported ES/No –  EsNo value. 

 

New MODCOD – Newly selected MODCOD. 
 
New Tx DataRate – New data rate based on new MODCOD and current symbol rate. 
 
Click [Clear ACM Events] to clear all ACM statistics from the buffer. 
 

 