5.4.4.3.1.2.2 Configuration | Interface | E1 | Time Slots
Figure 6‐11. Configuration | Interface | E1 | Time Slots page
Time Slot Configuration
Time Slots may be selected for transmission or reception up to the maximum dictated by the
selected transmit or receive data rate, and may be selected in prioritized order. For example, if
the Time Slot format is set to Mostly 64k TCHs (Time Channels), the maximum number of Time
Slots that can be dropped or inserted is 64 kbps. From left to right:
• Slot (read‐only) – This column identifies the assignable Time Slot (0 through 31).
• Selection On / Off – Select this Time Slot as On or Off.
• Priority – Use the drop‐down menu to select this Time Slot priority as Priority 1, Priority 2,
or Priority 3.
• Format – Use the drop‐down menu to select this Time Slot format as Mostly 8k TCHs,
Mostly 16k TCHs, Mostly 32k TCHs, or Mostly 64k TCHs.
Click [Submit] to save.