2 configuration | demod (demodulator) – Comtech EF Data ODM-840 User Manual

Page 112

background image

ODM/R-840 Outdoor Remote Router

Revision 0

Ethernet-based Remote Product Management

MN-ODM840

5–24

5.4.4.3.2

Configuration | Demod (Demodulator)

Use this page to configure ODM/R‐840 Rx demodulator operations. 
 
 

Figure 6‐12. Configuration | Demod page 

Demodulator

 

The  upper  range  of  Symbol  Rate  selection  requires  activation  of  the  ‘RECEIVE 
SYMBOL RATE’ FAST option. 

 
The acceptable/valid operating range for each item in this section is provided in parentheses. 
 
Data  Rate  (read‐only)  –  This  section  displays  the  data  rate,  which  is  a  snap  shot  of  the 

MODCOD currently being received. 
 

Symbol Rate (1000‐62000 ksps) – Enter the Active and Alternate symbol rates in ksps. 
 
Click [Submit] to save these settings. 
 
Rx Frequency (950‐2150 MHz) – Enter the Active and Alternate Rx frequencies in MHz.  