Output scpi command subsystem, Output scpi command summary, Output scpi command reference – AMETEK SFA Series Ethernet Programming User Manual
Page 90
SCPI Command Operation
SG Series Programming
6-18
M550129-03 Rev K
6.7
OUTPUT SCPI COMMAND SUBSYSTEM
This section first presents a tree summary of the OUTPut commands and
then provides a tabular description.
6.7.1
OUTPUT SCPI Command Summary
OUTPut
:ISOLation
:ISOLation?
:POLarity
:POLarity?
:PROTection
:DELay
:DELay?
:FOLD
<0|1|2>
:FOLD?
:SENSe
:SENSe?
:STATe
:STATe?
:TRIPped?
6.7.2
OUTPUT SCPI Command Reference
The letter “C” in the “SCPI” column means that the command syntax is
SCPI compliant; an “N” in the “SCPI” column means that the command
syntax is not part of the SCPI definition.
Command
Description
SCPI
OUTPut
Output subsystem.
C
:ISOLation
Sets the rear panel isolation relay control signal ON or OFF. Valid
arguments are 1/ON or 0/OFF.
N
:ISOLation?
Returns the state of the rear panel isolation relay control signal: 1 =
ON 0 = OFF
N
:POLarity
Changes the state of the polarity relay. This command requires that
the isolation relay be open beforehand. If the isolation relay is
closed when this command is attempted, the state of the polarity
relay will not change, and an error message will be generated.
C
:POLarity?
Returns the state of the polarity relay:
C
:PROTection
Output Protection subsystem.
N
:DELay
Sets the programmable time delay executed by the supply before
reporting output protection conditions after a new output voltage or
current is specified. Functional granularity of +/- 0.5 seconds
N
:DELay?
Returns the time delay to be executed by the supply.
N