Ethernet Configuration and Remote Programming

SG Series Programming

5-18

M550129-03 Rev K

To change:

Type the new name (15 characters maximum) in
the blank field provided and click Apply to
update (or make all desired changes before
clicking Apply).

Description: you may change the default factory setting to something
more meaningful to your current setup.

To change:

Type your customized description, up to 36
characters, in the blank field provided, and click
Apply to update (or make all desired changes
before clicking Apply).

TCP/IP Configuration: the power supply has two TCP/IP configurations
that can be set, Primary and Secondary. If the Primary Configuration is
not valid on your network, the power supply will attempt to try the
Secondary Configuration.

NOTE: The power supply will NOT try the Secondary Configuration if you
have selected the Primary Configuration options, Obtain an IP Address
Automatically
and Auto IP Enabled.

You may statically assign an IP address as well as configure other
Ethernet/LAN parameters, or you may keep/return to its default setting for
automatic assignment of an IP address.

To assign:

Click the radio button next to Use a Static IP
Address
to manually configure some or all of the
following the Ethernet/LAN parameters:

IP Address – input any standard IP address.
(Factory setting is 192.168.0.200). After clicking
Apply, you also must reset the power supply and
then exit and restart the Web browser to effect
this change. If you have changed the network
portion of the IP address, it may be necessary to
alter the network settings of your attached
computer to reconnect to the power supply.

Subnet Mask – input a value that identifies
which network segment your power supply is on,
consisting of 4 whole numbers, each ranging
from 0 through 255, separated by periods.
(Factory setting is 255.255.255.0, a class-C
network subnet mask). Click Apply to update (or
make all desired changes before clicking Apply).

Gateway – input the IP Address of any gateway
that stands between the instrument and any
other network entities that communicate with the
power supply. (No factory setting). Click Apply to
update (or make all desired changes before
clicking Apply).

DNS Server – input an IP address for the Domain
Name System (DNS) server. Click Apply to