SG Series Programming

SCPI Command Operation

M550129-03 Rev K

6-55

to 3.82 volts in 0.1 sec

PROG:DEF 8, RAMPTOV, 3.82, 3.46, 5, 20, 0.1

//ramp from 3.82 volts down

to 3.46 volts in 0.1 sec

PROG:DEF 9, RAMPTOV, 3.46, 3.12, 5, 20, 0.1

//ramp from 3.46 volts down

to 3.12 volts in 0.1 sec

PROG:DEF 10,RAMPTOV, 3.12, 2.83, 5, 20, 0.1

//ramp from 3.12 volts down to

2.83 volts in 0.1 sec

PROG:DEF 11,RAMPTOV, 2.83, 2.56, 5, 20, 0.1

//ramp from 2.83 volts down to

2.56 volts in 0.1 sec

PROG:DEF 12,RAMPTOV, 2.56, 2.31, 5, 20, 0.1

//ramp from 2.56 volts down to

2.31 volts in 0.1 sec

PROG:DEF 13,RAMPTOV, 2.31, 2.10, 5, 20, 0.1

//ramp from 2.31 volts down to

2.10 volts in 0.1 sec

PROG:DEF 14,RAMPTOV, 2.10, 1.90, 5, 20, 0.1

//ramp from 2.10 volts down to

1.90 volts in 0.1 sec

PROG:DEF 15,RAMPTOV, 1.90, 1.72, 5, 20, 0.1

//ramp from 1.90 volts down to

1.72 volts in 0.1 sec

PROG:DEF 16,RAMPTOV, 1.72, 1.55, 5, 20, 0.1

//ramp from 1.72 volts down to

1.55 volts in 0.1 sec

PROG:DEF 17,RAMPTOV, 1.55, 1.40, 5, 20, 0.1

//ramp from 1.55 volts down to

1.40 volts in 0.1 sec

PROG:DEF 18,RAMPTOV, 1.40, 1.27, 5, 20, 0.1

//ramp from 1.40 volts down to

1.27 volts in 0.1 sec

PROG:DEF 19,RAMPTOV, 1.27, 1.15, 5, 20, 0.1

//ramp from 1.27 volts down to

1.15 volts in 0.1 sec

PROG:DEF 20,RAMPTOV, 1.15, 1.04, 5, 20, 0.1

//ramp from 1.15 volts down

to 1.04 volts in 0.1 sec

PROG:DEF 21, RETURN

//step 21 may only be a

STOP

,

RETURN

, or

GOTO

PROG:STAT COMPLETE

PROG:SAVE:SEL

PROG:STAT?

Response: Ram[88]=“STOPPED”,Slave[88]=”STOPPED”

To run the combined sequence, simply select the first sequence, and then run it.