AMETEK SFA Series Ethernet Programming User Manual
Page 67
SG Series Programming
Ethernet Configuration and Remote Programming
M550129-03 Rev K
5-27
Stop Current: the programmed current setting when you exit power
mode
Stop OVolt: the programmed overvoltage setting when you exit power
mode
STOP: puts into effect the newly programmed settings and exits power
mode
CC and CV indicators: presently operating output mode of the power
supply, either constant voltage or constant current.
OVP indicator: highlighted red if over voltage protection is activated
FAULT indicator: highlighted red if fault has occurred
OUTPUT indicator: solid-lit shows power output status is On
If you have Read/Write access, you can change the following settings
(after inputting desired settings, click EXECUTE/UPDATE):
•
Max Volts: click in the Max Volts field and input a new value for
voltage.
•
Max Current: click in the Max Current field and input a new value
for current.
•
Max Watts: click in the Max Watts field and input a new value for
power.
If you have Read/Write access, you can change the following settings
(after inputting desired settings, click STOP):
•
Stop Volts: click in the Stop Volts field and input a new value for
voltage.
•
Stop Current: click in the Stop Current field and input a new value
for current.
•
Stop OVolt: click in the Stop OVolt field and input a new value for
overvoltage protection.