SG Series Programming

Ethernet Configuration and Remote Programming

M550129-03 Rev K

5-21

5.5.3

SETTINGS

The Settings page is available to users who have FULL, Read/Write or Read
Only access to at least one power supply (Read Only users can make no
changes to the settings). In this page you will see continuous updates (2-5
times per second) of the actual voltage output (value displayed on the left)
and the actual live current output (value displayed to the right).

Figure 5-14. Settings Page

Voltage: value above is updated with actual voltage output of the power
supply

Current: value above is updated with actual live current output

Set V: the programmed voltage setting

Set I: the programmed current setting

Set OVP: the programmed over voltage protection setting

APPLY: puts into effect the newly input settings

CC and CV indicators: presently operating output mode of the power
supply, either constant voltage or constant current.

OVP indicator: highlighted red if over voltage protection is activated