Ethernet Configuration and Remote Programming

SG Series Programming

5-26

M550129-03 Rev K

5.5.5

POWER

The Power page (only in SGI) displays updated information for the following
parameters:

Figure 5-17. SGI Power Page (not in SGA)

Volts: value above is updated with actual voltage output of the power
supply

Current: value above is updated with actual live current output of the
power supply

Power (kW): value above is updated with actual power output of the
power supply

Max Volts: the programmed voltage setting limit

Max Current: the programmed current setting limit

Max Watts: the programmed power setting limit

EXECUTE/UPDATE: puts into effect the newly programmed limits

Stop Volts: the programmed voltage setting when you exit power mode