Description
Sorensen Power Supply SGx
IP Address
DHCP-acquired (Primary default*) If DHCP absent,
assigned via Auto-IP (Secondary default*)
IP Addressing mode
DHCP-acquired (Primary default*)
Subnet Mask
DHCP-acquired (Primary default*) If DHCP absent,
assigned via Auto-IP (Secondary default*)
Gateway
0.0.0.0
DNS Server
0.0.0.0
Listening Port
9221
User ID
admin
Password
password
Ping Echo
On
* Primary/Secondary defaults:
The Ethernet interface provides the opportunity to set both a Primary and
a Secondary IP configuration in the IP Configuration page (Section 5.5.2).
If the Primary fails, the system defaults to the Secondary configuration.
However, both setting “DHCP-acquired” and selecting “Auto IP Enabled”
together in the Primary configuration, prevents the power supply from
trying the Secondary configuration. Please see “TCP/IP Configuration”
and “Auto IP Enabled” under IP Configuration, Section 5.5.2 for more
detail.
4.3.3
Programming Resolution
SGA
SGI
Voltage
0.002% of full scale
0.002% of full scale
Current
0.002% of full scale
0.002% of full scale
Overvoltage
Protection
0.002% of full scale (full scale is 110% of
max output voltage.)
0.002% of full scale (full
scale is 110% of max
output voltage.)
4.3.4
Programming Accuracy
SGA
SGI
Voltage
± (0.1% of maximum output voltage)
± (0.1% + 0.1% of full scale)
Current
± (0.25% of full scale output current
± (0.1% + 0.4% of full scale)
Overvoltage
Protection
± (0.5% of max output voltage)
±
(0.5% + 0.5% of full scale)
(full scale 110% of max. output
voltage)
4.3.5
Readback Resolution
SGA
SGI
Voltage
0.002% of full scale
0.02% of full scale
Current
0.002% of full scale
0.02% of full scale