SGI MEASURE SCPI Command Subsystem
The POWer query was added to the Measure subsystem only in SGI to
measure power once it is set up. (Section 6.6 contains the Measure
commands that can be used in both SGA and SGI):
MEASure:POWer?
(Available only with SGI power supplies – see Section 6.13.)
The letter “C” in the “SCPI” column means that the command syntax is SCPI compliant;
an “N” in the “SCPI” column means that the command syntax is not part of the SCPI
definition.
Command
Description
SCPI
MEASure
N
:POWer?
Returns the value for present power in watts being
dissipated by the load. The power is measured by taking
voltage and current measurement pairs three times, and
averaging the result to a single wattage reading.
N
6.13.5
SGI HTRIGGER SCPI Command Subsystem
This section applies only to units with the External User Interface
(Currently only available on Ethernet versions).
The SEQuence command was added to the Htrigger subsystem only in
SGI to trigger a preprogrammed ramp or sequence. (Sections 6.10
contains the Htrigger commands that can be used in both SGA and SGI).
HTRIGger:SEQuence
(Available only with SGI power supplies – see Section 6.13.)
The letter “C” in the “SCPI” column means that the command syntax is SCPI compliant; an
“N” in the “SCPI” column means that the command syntax is not part of the SCPI definition.
Command
Description
SCPI
HTRIGger
N
:SEQuence
Loads
a
Sequence to be initialized by the external Hardware
T
rigger
.
This command must be followed by the HTRIG:ARM command
before the Hardware Trigger becomes operational.
N
:SEQuence?
Returns the currently loaded sequence name
N