Readback functions, Specifications – AMETEK SFA Series Ethernet Programming User Manual
Page 22
IEEE/GPIB Features, Functions, Specifications
SG Series Programming
2-2
M550129-03 Rev
K
2.4
READBACK FUNCTIONS
•
Actual measured voltage and current
•
Voltage and current settings
•
Soft voltage and current limits
•
Overvoltage protection setting
•
Status and Accumulated Status registers
•
Programming error codes
•
Fault codes
•
Manufacturer, power supply model, and firmware version identification
2.5
SPECIFICATIONS
Specifications are subject to change without notice. Refer to your SGA or SGI
power supply operation manual for effects of line regulation, load regulation,
and temperature on accuracy specifications.
2.5.1
Programming Resolution
Voltage:
0.002% of full scale
Current:
0.002% of full scale
Overvoltage Protection: 0.002% of full scale (full scale is 110% of max
output voltage.)
2.5.2
Programming Accuracy
Voltage:
± ( 0.1% of maximum output voltage)
Current:
± ( 0.4% of maximum output current)*
Overvoltage Protection: ± (1.0% of max output voltage)
* After 30 minutes operation with fixed line, load, and temperature.
2.5.3
Readback Resolution
Voltage:
± 0.002% of full scale
Current:
± 0.002% of full scale
2.5.4
Readback Accuracy
Voltage:
± ( 0.15% of full scale output voltage)
Current:
± ( 0.4% of full scale output current)*